Bogen PCMTIM Specifiche

Navigare online o scaricare Specifiche per Telefoni Bogen PCMTIM. Bogen PCMTIM Specifications Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - PCM Paging Control System

PCM Paging Control SystemInstallation and Use Manual© 1999 Bogen Communications, Inc.All rights reserved. 54-2011-01 9910Model: LUPCMALLPEC Code: 532

Pagina 2

Figure 4-1: LUPCMALL Feature Callouts[10]

Pagina 3 - Contents

[11]Descriptions and LocationsRefer to Figure 4-1.1. TEL INT SEL Switch Bank - Sets telephone interface type for the TEL LINE jack on the PCMTIM modul

Pagina 4

[12]15. TALK BACK Switch Bank - Determines if a 70V speaker zone will operate as a two-way hands-free talk backzone or as a one-way paging zone (see S

Pagina 5 - Introduction

❑5.System Wiring Connections5.1. Telephone System ConnectionsThe PCMTIM module is the telephone interface module for the PCM Paging Control System. Th

Pagina 6 - 1.4. Other Features

IMPORTANT: The polarity of the Tip & Ring contacts of the RJ11 jack for the Tel Line and Over Ride were chosenso that when a standard modular cord

Pagina 7 - 2. Before You Start

4. Use 24-gauge solid wire to connect the GND ST terminal on the module to the PBX ground. This is typically theAC ground for the PBX system.IMPORTANT

Pagina 8

The unit will also respond to CPC pulses (short losses of loop current). When a CPC pulse is detected, the unit willimmediately drop the line.1. Make

Pagina 9 - 3. Installation

The night ringer normally sounds a simulated ring tone but can be programmed to sound a chime tone. Refer toSystem Programming, Section 11 to set up a

Pagina 11 - Descriptions and Locations

[19]6. Paging Amplifier ConnectionsThe paging amplifier audio connections are made to the PCMTBM module terminal strip. If the amplifier has apaging

Pagina 12

© 1999 Bogen Communications, Inc.All Rights Reserved. Printed in U.S.A.NoticeEvery effort was made to ensure that the information in thisguide was com

Pagina 14

The PCM system is very flexible in how it can provide background music throughout the system:• Background music can be continuously supplied to all zo

Pagina 16 - 5.6. Night Ringer

7.2. Background Music Continuously Supplied To All Zones Not Being PagedSee Figure 7-1 on page 20 for connection with a high-powered background music

Pagina 21 - 7. Background Music

[28]This page intentionally left blank

Pagina 22

[29]8.1. Wiring to 70V SpeakersSee Figure 8-2 on page 30 for wiring.NOTE: Make sure PCMZPM OUTPUT switch is set to HI PWR. To set the switch, remove t

Pagina 23

[3]Contents1. Introduction...5

Pagina 24

Figure 8-2: Zone Wiring to Speakers[30]

Pagina 26

Figure 9-1: Connection of Relays to the Relay Driver Outputs[32]

Pagina 27

[33]9.1. CPU to Emergency SignalingExternal input control is available to trigger a tone signal from the PCM over the paging system. Shorting EM/SC to

Pagina 28

[34]This page intentionally left blank

Pagina 29 - 8.1. Wiring to 70V Speakers

[35]10.1. Power-Up SequenceAll equipment in the paging system should remain off until the system wiring is completed. This is the recommendedpower-up

Pagina 30

[36]This page intentionally left blank

Pagina 31

[37]System programming lets you set certain PCM options and tone features using the DTMF keys of a telephone. Italso lets you to program paging zone g

Pagina 32

[38]11.1. Programming Paging Zone Groups32 paging zone groups can be created. Each zone group can consist of up to 99 zones. To create a zone group:1.

Pagina 33 - 9. Optional Wiring

[39]11.6. Single Amp BGM EnableSingle amplifier BGM operation lets the PCM use the paging amplifier to provide high-powered BGM to passivespeakers whe

Pagina 34

[4]8. Zone Speaker Wiring and Setup ...318.1. Wiri

Pagina 35 - Associated Equipment

[40]11.11. Relay ContactsThe PCM system provides a set of dual "C-form" contacts which can be used to activate external equipment. Therelay

Pagina 36

[41]FEATURE FEATURE CODE ADDITIONAL DATA DEFAULTPrivacy Beep Inhibit 006Enable 007 EnablePre-Announce ToneInhibit 003Beep 004Chime 005 ChimeConfirmati

Pagina 37 - 11. System Programming

[42]FEATURE FEATURE CODE ADDITIONAL DATA DEFAULTEM/SCZone Group *92 Zone Numbers All CallNo Tone 020Follow Contact 0212-Second Tone 0223-Second Tone 0

Pagina 38

[43]FEATURE FEATURE CODE ADDITIONAL DATA DEFAULTTime Trigger 2Zone Group *82 Zone Numbers No ZonesInhibit 120 InhibitEnable 121 HHMM See Note (page 44

Pagina 39

[44]FEATURE FEATURE CODE ADDITIONAL DATA DEFAULTTime Trigger 6Zone Group *86 Zone Numbers No ZonesInhibit 160 InhibitEnable 161 HHMM See Note 3 (below

Pagina 40 - 11.11. Relay Contacts

[45]13.1. Paging ZonesThe PCM system supports from 3 to 99 different paging zones (in groups of 3). It also supports up to 32 pagingzone groups for vo

Pagina 41

[46]13.5. How To Make A Code CallCode calling is the ability to activate a series of chime tones over a signalling zone group (the specific zones in t

Pagina 42

[47]13.7. How To Make An Echo Code CallRefer to System Programming, Section 11, for instructions on how to activate this feature and to select the typ

Pagina 43

[48]This page intentionally left blank

Pagina 44

[49]14. Testing and TroubleshootingFunctional Test GuideUse the following chart to verify proper operation after installation. To start the test,pick

Pagina 45 - 13. Paging: How To Use The

1.IntroductionThe PCM Paging Control System (see Figure 1-1) is an expandable zone paging and signaling system. TheLUPCMALL consists of 4 pre-assemble

Pagina 46 - 13.5. How To Make A Code Call

[50]Procedure ARefer to Figure 14-1 on page 51.1. Disconnect PCM from the telephone system.2. Set dip Switch 3, 4, and 5 to ON and 1, 2, 6, and 7 to O

Pagina 47

Figure 14-1: Test Procedure A.[51]

Pagina 49 - Functional Test Guide

Typical Connections* To Slave Amps (see Figure A-2 on page 54) * To Ambient Level Controller (see Figure A-3 on page 55) * To Call Stacker (see Figure

Pagina 51

Figure A-3: Typical Application - Connecting to an Ambient Level Controller[55]

Pagina 52

Figure A-4: Typical Application - Connection to a Call StackerFigure A-5: Typical Application - Connection to a Digital Feedback Eliminator[56]

Pagina 55

[59]Confirmation Tone - A double-beep tone heard by the caller after dialing the paging access number and beforeentering the desired zone number. The

Pagina 56

[6]1.2. Background Music• High/Low-Power distributed (buffered for up to 50 amplified speakers)• High/Low-Powered, using dedicated BGM amplifier• High

Pagina 57

[60]This page intentionally left blank

Pagina 58

[61]1-Amp BGM: Enabling this feature allows a single amp to provide background music (BGM) and pagingthroughout the system (BGM is lost in all zones d

Pagina 59 - Appendix B: Tones

[62]Time Triggers (1-8): Eight separate time-triggered tones can be programmed into the PCM. A specific zone groupcan be programmed for each time-trig

Pagina 60

[63]Appendix D: Configuration Forms* Zone Configuration (Form D-1 on page 64)* Zone Group Map (Form D-2 on page 68)

Pagina 61 - Programmable Features

Form D-1: Zone ConfigurationPhysical Physical Music Talk Back Night RingDescription Zone Zone in Zone in Zone in ZoneNumber Code Y/N Y/N Y/N112233445

Pagina 62

Form D-1: Zone Configuration (Continued)Physical Physical Music Talk Back Night RingDescription Zone Zone in Zone in Zone in ZoneNumber Code Y/N Y/N

Pagina 63

Form D-1: Zone Configuration (Continued)Physical Physical Music Talk Back Night RingDescription Zone Zone in Zone in Zone in ZoneNumber Code Y/N Y/N

Pagina 64 - Form D-1: Zone Configuration

Form D-1: Zone Configuration (Continued)Physical Physical Music Talk Back Night RingDescription Zone Zone in Zone in Zone in ZoneNumber Code Y/N Y/N

Pagina 65

From D-2. Zone Groups MapPhysical PhysicalDescription Zone Zone Zones Contained In GroupGroup Code1 *012 *023 *034 *045 *056 *067 *078 *089 *0910 *101

Pagina 66

[7]2. Before You Start2.1. Select OptionsBefore setting up your system, use the checklist below to assist you in setting up and programming the PCMPag

Pagina 67

Figure 3-1: Rack Mounting the LUPCMALL Paging Control System[8]

Pagina 68 - From D-2. Zone Groups Map

[9]3.1. Adding PCMZPM ModulesThe LUPCMALL is pre-assembled to accommodate 3 zones of paging. If your installation requires 4 to 9 zones, youcan add on